ACCA Manual J, S, & D - Load Calculations

Manual J, S, & D - Load Calculations 

Established in 1978 | 24/7 Emergency Services | FREE On-Site Estimates

This is a placeholder for the Yext Knolwedge Tags. This message will not appear on the live site, but only within the editor. The Yext Knowledge Tags are successfully installed and will be added to the website.

Established in 1978

24/7 Emergency Services

FREE On-Site Estimates

Hours:

This is a placeholder for the Yext Knolwedge Tags. This message will not appear on the live site, but only within the editor. The Yext Knowledge Tags are successfully installed and will be added to the website.

Manual J, S, & D - Load Calculations

Established in 1978

24/7 Emergency Services

FREE On-Site Estimates

Hours:

This is a placeholder for the Yext Knolwedge Tags. This message will not appear on the live site, but only within the editor. The Yext Knowledge Tags are successfully installed and will be added to the website.

Comfort & Efficiency starts with - ACCA Manual J, S, & D

Air Service Professionals Heating & Cooling Specialists preforms ACCA Manual J, S, & D load calculations to properly size your homes heating & cooling system(s) & ductwork. Ensuring comfort & efficiency for your family & home. 


Louisiana Energy Code requires load calculations be preformed on all new construction residential homes. We take a step further & also preform Manual J, S, & D load calculations on existing homes to ensure your replacement heating & cooling system & ductwork are properly sized for your home. Properly sized heating & cooling systems increase the comfort of the occupants by providing proper dehumidification in addition to the necessary heating & cooling capacity to maintain temperature. This process also improves the efficiency & life span of the system.   

Manual J, S & D Load Calculations - What is the meaning? 

Manual J - (Joule - Measurement of Heat) Determines a home's heat loss/gain. The factors that are used to determine this calculation are number of occupants, attic & exterior walls materials, insulation, foundation, window & doors, ductwork tightness & type, the homes tightness, lighting, appliances & orientation.   

 

Manual S - (System Selection) Includes using manufacture's performance data showing sensible, latent, & total capacities of the system. Using the data from the Manual J, matching a heating & cooling system to your homes heat loss/gain.     

 

Manual D - (Ductwork Design) Includes using the Manual S selected equipment blower data, fittings, lengths, filter type & room by room cfm requirements for both supply/return sizing. Ensuring a quiet, low static & balanced ductwork system.


All (3) reports put together equal a properly sized heating/cooling system & ductwork to meet your homes exact needs. No guessing or rule of thumbs just accurate sizing of equipment & ductwork to properly heat & cool, dehumidify, provide indoor air quality, & operate efficiency in your home. For more details click on Air Service Professionals Sizing/Design Procedures, Air Pros - New Construction Builders List, & the (3) Guides to Building a Energy Efficient. 

 